Magnatrol Valve Corp.

Product Catalog


Search Catalog
      GO   
 All Categories    Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
All Categories > Stainless Steel Solenoid Valves > Liquids and Gases ( – 350°F to 400°F) > Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
> View Items
 

Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated

Check up to five results to perform an action.


Max. Diff. Pressure 500 PSI
Pipe Size Inches 1/2" to 2"

Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the laminated plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.

No Differential Pressure Required to Open
Max. Static Pressure - 300 PSI (Except valves listed for 500 PSI diff.)
Consult factory: For Stainless Steel Strainers 1/2, 3/4, 1, 1 1/2 and 2 inch. For 150-300 PSI flanges.





    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
Compare Items
   
  Results 1 - 23 of 23 1 

Item #

Item Name

Pipe Size

Maximum Differential Pressure

Watts AC

Watts DC

14K42 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1/2 Inch 110 psi 25 18
14K32 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1/2 Inch 200 psi 25 18
29K52 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1/2 Inch 300 psi 45 23
E29K62 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1/2 Inch 500 psi 45 23
14K43 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3/4 Inch 110 psi 25 18
29K33 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3/4 Inch 200 psi 45 23
129K53 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3/4 Inch 300 psi 65 33
E129K63 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3/4 Inch 500 psi 65 33
16K44 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1 Inch 110 psi 25 18
31K34 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1 Inch 200 psi 45 23
131K54 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1 Inch 300 psi 65 33
E131K64 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1 Inch 500 psi 65 33
35K46 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1-1/2 Inch 115 psi 45 23
41K36 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1-1/2 Inch 200 psi 60 35
141K56 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1-1/2 Inch 300 psi 85 45
141K66 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
1-1/2 Inch 500 psi 85 45
36K47 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
2 Inch 100 psi 45 23
42K37 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
2 Inch 200 psi 60 35
42K57 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
2 Inch 300 psi 60 35
142K67 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
2 Inch 500 psi 85 45
44K49F1 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3 Inch 100 psi 60 35
44K39F1 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3 Inch 200 psi 60 35
144K59F3 Normally Closed

Type K Full Port Stainless Steel Solenoid Valves- Internal Pilot Operated
3 Inch 300 psi 85 45
  Results 1 - 23 of 23 1 


Home | Quote | Solenoid Coils | Position Indicator/Switch | Bronze Valves | Stainless Steel Valves | Strainers


Magnatrol Valve Corporation
P.O. Box 17 | Hawthorne, NJ 07507 | U.S.A.
Phone 973-427-4341 | Fax 973-427-7611
info@magnatrol.com

Copyright © 2001-2006 Magnatrol Valve Corp.